Ventiladores ATEX ATEX FANS 748 CV092024 THREE PHASE RANGE / serie trifásica 2 POLE / 2 POLOS 4 POLE / 4 POLOS Code Model R.P.M. Rated I (A) Rat. Power kW Air flow m3/h Sound dB (A) Weight Kg Connection diagram 230V 400V 501401816XY MBCA 180 T2 0,55kW ATEX 2800 2,23 1,29 1,29 1.230 48 19 1 501401818XY MBCA 180 T2 1,1kW ATEX 2800 4,05 2,33 2,33 1.800 52 25 1 501402018XY MBCA 200 T2 1,1kW ATEX 2800 4,05 2,33 2,33 1.800 52 27 1 501402027XY MBCA 200 T2 2,2kW ATEX 2800 7,97 4,58 4,58 2.880 57 33 1 501402219XY MBCA 220 T2 1,5kW ATEX 2800 5,46 3,14 3,14 2.160 53 32 1 501402229XY MBCA 220 T2 3kW ATEX 2870 10,3 5,92 5,92 3.960 59 41 1 501402529XY MBCA 250 T2 3kW ATEX 2870 10,3 5,92 5,92 3.240 56 51 1 501402532XY MBCA 250 T2 4kW ATEX 2890 13,3 7,63 7,63 4.680 60 60 1 501402834XY MBCA 280 T2 5,5kW ATEX 2900 - 10,6 10,6 4.680 60 82 1 501402836XY MBCA 280 T2 7,5kW ATEX 2900 - 14,1 14,1 6.120 63 90 1 Code Model R.P.M. Rated I (A) Rat. Power kW Air flow m3/h Sound dB (A) Weight Kg Connection diagram 230V 400V 501402242XY MBCA 220 T4 0,37kW ATEX 1400 1,86 1,07 1,07 1.800 41 28 1 501402542XY MBCA 250 T4 0,37kW ATEX 1400 1,86 1,07 1,07 1.800 44 30 1 501402543XY MBCA 250 T4 0,55kW ATEX 1400 2,57 1,49 1,49 2.520 47 33 1 501402844XY MBCA 280 T4 0,75kW ATEX 1390 2,83 1,63 1,63 3.000 47 40 1 501402845XY MBCA 280 T4 1,1kW ATEX 1400 4,33 2,49 2,49 3.800 51 42 1 501403146XY MBCA 310 T4 1,5kW ATEX 1400 5,67 3,26 3,26 4.300 52 50 1 501403154XY MBCA 310 T4 2,2kW ATEX 1430 8,07 4,64 4,64 5.400 56 58 1 501403554XY MBCA 350 T4 2,2kW ATEX 1430 8,07 4,64 4,64 5.400 53 66 1 501403556XY MBCA 350 T4 3kW ATEX 1430 10,7 6,17 6,17 7.200 56 66 1 501403559XY MBCA 350 T4 4kW ATEX 1440 14,5 8,32 8,32 7.920 59 76 1 501404061XY MBCA 400 T4 5,5kW ATEX 1440 - 10,5 10,5 7.920 58 100 1 501404063XY MBCA 400 T4 7,5kW ATEX 1440 - 14,1 14,1 10.800 62 108 1 501404563XY MBCA 450 T4 7,5kW ATEX 1440 - 14,1 14,1 10.080 57 112 1 501404552XY MBCA 450 T4 15kW ATEX 1460 - 29,8 29,8 18.000 66 170 1 501405052XY MBCA 500 T4 15kW ATEX 1460 - 29,8 29,8 16.200 61 200 1 501405055XY MBCA 500 T4 22kW ATEX 1470 - 40,1 40,1 21.600 66 272 1 501405655XY MBCA 560 T4 22kW ATEX 1470 - 40,1 40,1 21.600 61 313 1 501405658XY MBCA 560 T4 37kW ATEX 1430 10,7 6,17 6,17 32.400 69 497 1 6 POLE / 6 POLOS Code Model R.P.M. Rated I (A) Rat. Power kW Air flow m3/h Sound dB (A) Weight Kg Connection diagram 230V 400V 501403170XY MBCA 310 T6 0,37kW ATEX 900 2,2 1,27 1,27 2.160 42 43 1 501403171XY MBCA 310 T6 0,55kW ATEX 900 3 1,8 1,8 3.240 45 44 1 501403572XY MBCA 350 T6 0,75kW ATEX 910 3,39 1,95 1,95 3.960 47 56 1 501403573XY MBCA 350 T6 1,1kW ATEX 910 4,83 2,78 2,78 5.400 49 59 1 501404074XY MBCA 400 T6 1,5kW ATEX 940 6,45 3,71 3,71 5.400 48 82 1 501404078XY MBCA 400 T6 2,2kW ATEX 940 10,3 5,94 5,94 7.920 52 90 1 501404580XY MBCA 450 T6 3kW ATEX 960 12,7 7,3 7,3 9.000 52 112 1 501405083XY MBCA 500 T6 4kW ATEX 960 16,5 9,46 9,46 9.000 52 153 1 501405085XY MBCA 500 T6 5,5kW ATEX 960 - 12,8 12,8 10.800 56 153 1 501405687XY MBCA 560 T6 7,5kW ATEX 965 - 15,2 15,2 16.200 56 221 1 501405675XY MBCA 560 T6 11kW ATEX 970 - 22,6 22,6 21.600 61 233 1 501406375XY MBCA 630 T6 11kW ATEX 970 - 22,6 22,6 19.800 56 243 1 501406377XY MBCA 630 T6 18,5kW ATEX 975 - 35,7 35,7 28.800 63 400 1 ATEX CLASSIFICATION / clasificación ATEX ZONE / ZONA 1 ZONE / ZONA 2 ZONE / ZONA 22 POLVO CONDUCTIVO / CONDUCTIVE DUST POLVO NO CONDUCTIVO / NON CONDUCTIVE DUST FAN/VENTILADOR (Ex h IIB T4 Gb) + MOTOR (Ex eb IIC T4 Gb) FAN/VENTILADOR (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc) FAN/VENTILADOR (Ex h IIIB T135ºC Db) + MOTOR (Ex tb IIIC T135ºC Db) FAN/VENTILADOR (Ex h IIIB T120ºC Dc) + MOTOR (Ex tc IIIB T120ºC Dc) To place an order for an ATEX fan, you must replace the XY of the code with XE for zone 1, XN for zone 2, XC for zone 22 for conductive dust and XNC for zone 22 for non conductive dust. For non-sparking air passage and standardmotor, it must indicate XI / Para cursar un pedido de un ventilador ATEX se debe sustituir la XY del código por XE para zona 1, XN para zona 2, XC para zona 22 para polvo conductivo y XNC para zona 22 para polvo no conductivo. Para paso de aire antichispas y motor estándar debe indicar XI.
RkJQdWJsaXNoZXIy MTE4OTIxMQ==