CV.28.02.25 299 Code Model Rated. R.P.M. Rated I (A) Rat.Pow. kW Air flow CFM Sound db (A) Weight Kg 230V 400-460V Código Modelo R.P.M. nom. I nom. (A) P. Nom. kW Q máx. CFM Sonido db (A) Peso Kg 230V 400-460V 5024035156XN AAVA 350/P T2 0,37kW ATEX 3420 1.7 1.00 0.37 105 64 33 5024040166XN AAVA 400/P T2 0,55kW ATEX 3408 2.5 1.45 0.55 151 66 44 5024045176XN AAVA 450/P T2 0,75kW ATEX 3444 3.5 2.00 0.75 178 68 46 5024050186XN AAVA 500/P T2 1,1kW ATEX 3396 4.5 2.6 1.10 190 70 51 5024056196XN AAVA 560/P T2 1,5kW ATEX 3420 6.8 3.95 1.50 200 72 89 5024063196XN AAVA 631/P T2 1,5kW ATEX 3420 6.8 3.95 1.50 200 73 116 5024063276XN AAVA 632/P T2 2,2kW ATEX 3408 9.3 5.4 2.20 232 74 119 5024071296XN AAVA 711/P T2 3kW ATEX 3480 12.6 7.3 3.00 280 76 149 5024071326XN AAVA 712/P T2 4kW ATEX 3492 - 9.2 4.00 304 77 168 5024080326XN AAVA 801/P T2 4kW ATEX 3492 - 9.2 4.00 270 80 195 5024080346XN AAVA 802/P T2 5,5kW ATEX 3492 - 11.46 5.50 412 82 197 5024080366XN AAVA 803/P T2 7,5kW ATEX 3492 - 14.1 7.50 414 84 197 5024090216XN AAVA 901/P T2 11kW ATEX 3528 - 21.4 11.00 521 85 330 5024100266XN AAVA 1001/P T2 18,5kW ATEX 3528 - 34.4 18.50 795 89 442 5024100286XN AAVA 1002/P T2 22kW ATEX 3528 - 39.8 22.00 916 91 501 Code Model R.R.P. $ ZONE 1 ZONE 2 ZONE 22 Sparkproof * CONDUCTIVE DUST NON CONDUCTIVE DUST Código Modelo P.V.P $ ZONA 1 ZONA 2 ZONA 22 Antichispas * POLVO CONDUCTIVO POLVO NO CONDUCTIVO 5024035156XY AAVA 350/P T2 0,37kW ATEX 2,874.30 2,857.30 2,874.30 2,876.80 2,280.50 5024040166XY AAVA 400/P T2 0,55kW ATEX 3,339.60 3,251.80 3,339.60 3,272.40 2,645.30 5024045176XY AAVA 450/P T2 0,75kW ATEX 3,920.50 3,635.70 3,868.90 3,662.20 3,030.50 5024050186XY AAVA 500/P T2 1,1kW ATEX 4,188.40 3,895.80 4,127.30 3,925.00 3,257.90 5024056196XY AAVA 560/P T2 1,5kW ATEX 5,358.90 5,065.00 5,423.10 5,102.80 4,118.60 5024063196XY AAVA 631/P T2 1,5kW ATEX 5,722.40 5,428.50 5,786.60 5,466.20 4,482.30 5024063276XY AAVA 632/P T2 2,2kW ATEX 5,888.70 5,492.60 5,816.10 5,533.80 4,549.70 5024071296XY AAVA 711/P T2 3kW ATEX 7,148.10 6,768.20 7,066.60 6,826.30 5,601.00 5024071326XY AAVA 712/P T2 4kW ATEX 7,458.60 7,001.10 7,458.60 7,070.90 5,709.80 5024080326XY AAVA 801/P T2 4kW ATEX 8,625.30 8,167.90 8,625.30 8,237.70 6,841.30 5024080346XY AAVA 802/P T2 5,5kW ATEX 9,728.40 8,888.00 9,728.40 8,984.10 7,149.20 5024080366XY AAVA 803/P T2 7,5kW ATEX 9,719.80 8,944.20 9,719.80 9,043.10 7,314.60 5024090216XY AAVA 901/P T2 11kW ATEX 13,273.70 12,523.60 13,273.70 12,712.70 10,330.40 5024100266XY AAVA 1001/P T2 18,5kW ATEX 18,800.90 17,542.10 18,800.90 17,766.70 15,235.10 5024100286XY AAVA 1002/P T2 22kW ATEX 20,460.30 18,902.50 20,460.30 19,194.80 16,040.40 ZONE / ZONA 1 ZONE / ZONA 2 ZONE / ZONA 22 POLVO CONDUCTIVO / CONDUCTIVE DUST POLVO NO CONDUCTIVO / NON CONDUCTIVE DUST FAN/VENTILADOR (Ex h IIB T4 Gb) + MOTOR (Ex eb IIC T4 Gb) FAN/VENTILADOR (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc) FAN/VENTILADOR (Ex h IIIB T135ºC Db) + MOTOR (Ex tb IIIC T135ºC Db) FAN/VENTILADOR (Ex h IIIC T135ºC Dc) + MOTOR (Ex tc IIIB T120ºC Dc) ATEX CLASSIFICATION | CLASIFICACIÓN ATEX To place an order for an ATEX fan, you must replace the XY of the code with XE for zone 1, XN for zone 2, XC for zone 22 for conductive dust and XNC for zone 22 for non conductive dust. For non-sparking air passage and standard motor, it must indicate XI / Para cursar un pedido de un ventilador ATEX se debe sustituir la XY del código por XE para zona 1, XN para zona 2, XC para zona 22 para polvo conductivo y XNC para zona 22 para polvo no conductivo. Para paso de aire antichispas y motor estándar debe indicar XI. * Non-sparking air passage and standard motor. * Paso de aire antichispas y motor estándar. * NA-NOT AVAILABLE. * ND-NO DISPONIBLE. THREE PHASE RANGE | SERIE TRIFÁSICA 2 pole | 2 polos THREE PHASE RANGE | SERIE TRIFÁSICA 2 pole | 2 polos
RkJQdWJsaXNoZXIy MTE4OTIxMQ==