CV.28.02.25 301 Code Model Rated. R.P.M. Rated I (A) 400V Rat.Pow. kW Air flow CFM Sound db (A) Weight Kg 230V 400V Código Modelo R.P.M. nom. I nom. (A) P. Nom. kW Q máx. CFM Sonido db (A) Peso Kg 230V 400V 5025050196XN AAVC/N 500 T2 1,5kW ATEX 3420 6.8 3.95 1.50 466 61 43 5025056276XN AAVC/N 560 T2 2,2kW ATEX 3408 9.3 5.4 2.20 667 63 69 5025063326XN AAVC/N 630 T2 4kW ATEX 3492 - 9.2 4.00 692 67 133 5025063346XN AAVC/N 630 T2 5,5kW ATEX 3492 - 11.46 5.50 915 67 143 5025071366XN AAVC/N 710 T2 7,5kW ATEX 3492 - 14.1 7.50 1,003 71 204 5025071216XN AAVC/N 710 T2 11kW ATEX 3528 - 21.4 11.00 1,393 72 238 5025080216XN AAVC/N 800 T2 11kW ATEX 3528 - 21.4 11.00 1,035 75 254 5025080246XN AAVC/N 800 T2 15kW ATEX 3522 - 27.4 15.00 1,639 76 254 5025090286XN AAVC/N 900 T2 22kW ATEX 3528 - 39.8 22.00 1,829 78 404 5025100316XN AAVC/N 1000 T2 37kW ATEX 3546 - 66.7 37.00 2,008 82 577 5025100336XN AAVC/N 1000 T2 45kW ATEX 3552 - 78.00 45.00 3,494 83 657 5071050186XN AAVC/NR 500 T2 1,1kW ATEX 3396 4.5 2.6 1.10 365 60 40 5071056196XN AAVC/NR 560 T2 1,5kW ATEX 3420 6.8 3.95 1.50 447 62 66 5071063296XN AAVC/NR 630 T2 3kW ATEX 3480 12.6 7.3 3.00 607 65 118 5071063326XN AAVC/NR 630 T2 4kW ATEX 3492 - 9.2 4.00 767 65 132 5071071346XN AAVC/NR 710 T2 5,5kW ATEX 3492 - 11.46 5.50 831 70 200 5071071366XN AAVC/NR 710 T2 7,5kW ATEX 3492 - 14.1 7.50 1,036 71 200 5071080366XN AAVC/NR 800 T2 7,5kW ATEX 3492 - 14.1 7.50 702 74 214 5071080216XN AAVC/NR 800 T2 11kW ATEX 3528 - 21.4 11.00 1,420 75 248 5071090246XN AAVC/NR 900 T2 15kW ATEX 3522 - 27.4 15.00 1,207 77 333 5071090266XN AAVC/NR 900 T2 18,5kW ATEX 3528 - 34.4 18.50 1,802 78 345 5071100306XN AAVC/NR 1000 T2 30kW ATEX 3546 - 56.6 30.00 1,791 81 570 5071100316XN AAVC/NR 1000 T2 37kW ATEX 3546 - 66.7 37.00 2,469 82 570 Code Model R.R.P. $ ZONE 1 ZONE 2 ZONE 22 Sparkproof * CONDUCTIVE DUST NON CONDUCTIVE DUST Código Modelo P.V.P $ ZONA 1 ZONA 2 ZONA 22 Antichispas * POLVO CONDUCTIVO POLVO NO CONDUCTIVO 5025050196XY AAVC/N 500 T2 1,5kW ATEX 5,212.90 4,465.90 4,824.20 4,503.60 3,723.30 5025056276XY AAVC/N 560 T2 2,2kW ATEX 6,366.30 5,462.90 5,786.30 5,504.00 4,569.00 5025063326XY AAVC/N 630 T2 4kW ATEX 7,451.10 6,993.70 7,451.10 7,063.50 5,754.10 5025063346XY AAVC/N 630 T2 5,5kW ATEX 8,554.40 7,714.00 8,554.40 7,809.80 6,061.90 5025071366XY AAVC/N 710 T2 7,5kW ATEX 9,456.60 8,681.00 9,456.60 8,779.80 7,132.60 5025071216XY AAVC/N 710 T2 11kW ATEX 11,235.50 10,485.50 11,235.50 10,674.60 8,381.90 5025080216XY AAVC/N 800 T2 11kW ATEX 12,915.20 12,164.90 12,915.20 12,354.10 10,026.20 5025080246XY AAVC/N 800 T2 15kW ATEX 13,759.60 12,518.60 13,759.60 12,725.40 10,292.40 5025090286XY AAVC/N 900 T2 22kW ATEX 17,657.10 16,099.30 17,657.10 16,391.70 13,356.60 5025100316XY AAVC/N 1000 T2 37kW ATEX 24,859.00 21,761.40 24,859.00 22,155.20 18,370.40 5025100336XY AAVC/N 1000 T2 45kW ATEX 26,638.00 23,882.30 26,638.00 24,382.30 19,790.90 5071050186XY AAVC/NR 500 T2 1,1kW ATEX 5,043.00 4,297.20 4,528.90 4,326.50 3,659.40 5071056196XY AAVC/NR 560 T2 1,5kW ATEX 6,199.90 5,398.70 5,756.70 5,436.40 4,501.20 5071063296XY AAVC/NR 630 T2 3kW ATEX 7,140.70 6,760.70 7,059.10 6,818.80 5,645.10 5071063326XY AAVC/NR 630 T2 4kW ATEX 7,451.10 6,993.70 7,451.10 7,063.50 5,754.10 5071071346XY AAVC/NR 710 T2 5,5kW ATEX 9,465.20 8,624.80 9,465.20 8,720.70 6,967.40 5071071366XY AAVC/NR 710 T2 7,5kW ATEX 9,456.60 8,681.00 9,456.60 8,779.80 7,132.60 5071080366XY AAVC/NR 800 T2 7,5kW ATEX 11,136.00 10,360.60 11,136.00 10,459.40 8,777.00 5071080216XY AAVC/NR 800 T2 11kW ATEX 12,915.20 12,164.90 12,915.20 12,354.10 10,026.20 5071090246XY AAVC/NR 900 T2 15kW ATEX 15,626.50 14,385.60 15,626.50 14,592.40 12,151.30 5071090266XY AAVC/NR 900 T2 18,5kW ATEX 15,997.60 14,739.10 15,997.60 14,963.50 12,551.30 5071100306XY AAVC/NR 1000 T2 30kW ATEX 23,522.20 21,177.30 23,522.20 21,542.00 17,828.00 5071100316XY AAVC/NR 1000 T2 37kW ATEX 24,859.00 21,761.40 24,859.00 22,155.20 18,370.40 ZONE / ZONA 1 ZONE / ZONA 2 ZONE / ZONA 22 POLVO CONDUCTIVO / CONDUCTIVE DUST POLVO NO CONDUCTIVO / NON CONDUCTIVE DUST FAN/VENTILADOR (Ex h IIB T4 Gb) + MOTOR (Ex eb IIC T4 Gb) FAN/VENTILADOR (Ex h IIB T3 Gc) + MOTOR (Ex ec IIC T3 Gc) FAN/VENTILADOR (Ex h IIIB T135ºC Db) + MOTOR (Ex tb IIIC T135ºC Db) FAN/VENTILADOR (Ex h IIIC T135ºC Dc) + MOTOR (Ex tc IIIB T120ºC Dc) ATEX CLASSIFICATION | CLASIFICACIÓN ATEX To place an order for an ATEX fan, you must replace the XY of the code with XE for zone 1, XN for zone 2, XC for zone 22 for conductive dust and XNC for zone 22 for non conductive dust. For non-sparking air passage and standard motor, it must indicate XI / Para cursar un pedido de un ventilador ATEX se debe sustituir la XY del código por XE para zona 1, XN para zona 2, XC para zona 22 para polvo conductivo y XNC para zona 22 para polvo no conductivo. Para paso de aire antichispas y motor estándar debe indicar XI * Non-sparking air passage and standard motor * Paso de aire antichispas y motor estándar. * NA-NOT AVAILABLE * ND-NO DISPONIBLE. THREE PHASE RANGE | SERIE TRIFÁSICA 2 pole | 2 polos THREE PHASE RANGE | SERIE TRIFÁSICA 2 pole | 2 polos
RkJQdWJsaXNoZXIy MTE4OTIxMQ==