Product out of catalogue
HC
Model
HC 56 T4/T8 1,5/0,25kW (A2:9)
Code
26261629__PV

HC 56 T4/T8 1,5/0,25kW (A2:9)

SHORT CASE VARIABLE PITCH BLADES FAN

MANUFACTURING FEATURES:
• Plate axial fan with circular reinforced frame.
• Motor-impeller modular assembly for complete versatility.
• Polyester powder finishing coat.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz for single phase motors, 230/400V 50Hz for three phase motors up to 4kW and 400/690V 50Hz for higher powers.
• HC: Polypropylene impeller (A2 profile) or polyamide impeller reinforced with fibreglass (other profiles) with variable pitch angle.
• HCA: Cast aluminum impeller with variable pitch angle.

APPLICATIONS:
Designed for wall or duct installation, they are suitable for:
• Air renewal in buildings and industries.
• Smoke exhaust (maximum 50-60ºC).
• Maximum working temperature: 50ºC single phase, 60ºC three phase.

UNDER REQUEST:
• Supply impeller (air direction from impeller to motor), 100% reversible impeller.
• 60Hz fans and special voltages.
• Hot-dipped galvanized or stainless steel housing.
• Optional can be adapted an square plate to the frame, to transform it in an axial square frame version fan.

Fan

Max flow
13610 m³/h
Weight
55 Kg

Motor

Power
1,5/0,25 kW
RPM Motor
1380/700
I max. 400 V
4/1,5
Size
90L
Efficiency
75/57 %
FP
0.83/0.49
HC 56 T4/T8 1,5/0,25kW (A2:9)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

HC 56 T4/T8 1,5/0,25kW (A2:9)

Dimensions scheme
C' E O ØA ØB ØDint ØJ
397 250 12x30º 646 620 559 12

HC 56 T4/T8 1,5/0,25kW (A2:9)

Electrical scheme

HC 56 T4/T8 1,5/0,25kW (A2:9)

Model
RP 56
Code
960330100
Information
PROTECTION GUARD FOR LONG CASE FANS

CONSTRUCTION FEATURES

• Protective grille on the motor and propeller side to prevent objects from entering. For HC and HCA models, the RP grille is only applicable on the propeller side. The RP is also suitable for the HMR EVO range, both for intake and discharge (note that the grille is of different sizes depending on whether it is for intake or discharge)
• Constructed with electro-welded rod.
• Compliant with ROHS directive 2002/95/EC.

ON REQUEST

• Grille in 304 or 316 stainless steel with electropolished finish.

Model
RP1 562
Code
960003657
Information
INLET PROTECTION GUARD FOR AXIAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of welded metal wire.
• According to ROHS 2002/95/EC Directive.

UNDER REQUEST

• Stainless guard 304 or 316 with electro-polished finishing coat.

Model
PCP 56
Code
963250105G
Information
PLASTIC GRAVITY SHUTTER

Gravity shutter.
The shutter will open by air force and will close when the fan is stopped.
Made of ABS plastic.
UV rays protected.
Note: Maximum air speed 16 m/s

Model
PO 56
Code
960001657
Information
CASE FANS MOUNTING SUPPORT

MANUFACTURING FEATURES

• Made of steel and protected against corrosion with polyester resin powder.

Model
AC 560
Code
960003215
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
BA-400 56
Code
960002056
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Fire classification: M0.

Model
SIL-C 560/560
Code
960056056
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-C 560/840
Code
960056084
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-C 560/1120
Code
960056112
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 560/560
Code
961056056
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 560/840
Code
961056084
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 560/1120
Code
961056112
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
PC2 60
Code
PC26060
Information
ALUMINIUM GRAVITY SHUTTER

• Overpressure backward damper for facade made of extruded aluminum and standard natural aluminum finishing.
• It incorporates weatherstrip in the fins to achieve greater efficiency in the closure and noise damping.
• Maintains overpressure or depression inside a room with respect to the outside or other adjacent rooms.
• Drills incorporated in frame for wall or duct fixing with screws or rivets.
• Recommended maximum air passage speed 6m/s. maximum temperature of 80ºC.

Model
BAD 14 (Ø560)
Code
960003464
Information
CIRCULAR-CIRCULAR ANTI-VIBRATION FLANGE

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0: from -50ºC to +200ºC in continuous and 400ºC/2h

Model
INT 25 6P A
Code
INT256PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

HC 56 T4/T8 1,5/0,25kW (A2:9)

Spare parts scheme
Code Family Name Qty Angle
1 R-H56029437ASTD ALUMINIUM IMPELLER 560:AA2:9 G37,5 D24 x1 38
1 R-H56029437PSTD IMPELLER 560:AP2:9 G37,5 D24 x1 38
1 R-H56029443ASTD ALUMINIUM IMPELLER 560:AA2:9 G43 D24 x1 43
1 R-H56029443PSTD IMPELLER 560:AP2:9 G43 D24 x1 43