fan image
Model
MBPV 35 T2 2,2kW ATEX Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)
Code
510603527XD

MBPV 35 T2 2,2kW ATEX Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)

ATEX ROOF FAN WITH BACKWARD IMPELLER AND PLASTIC CONSTRUCTION 

MANUFACTURING FEATURES:

• PE-el moulded housing and base (until size 45) and PP-el welded housing and base (for upper models).
• Backward impeller with self-cleaning system in PP welded plastic.
• Stainless steel nuts and bolts.
• Standard asynchronous squirrel-cage motor, IP-55, class F insulation. Standard voltages 230/400V 50Hz for motors until 4kW and 400/690V 50Hz for higher motors. Equipped with ATEX motor.

APPLICATIONS:

Designed for roof installation, they are suitable for:
• Corrosive air transport.
• Chemical and petrochemical industry.
• Laboratories and gas cabinets.
• General ventilation in closed environments classified as ATEX zone 2.
• Maximum temperature of transported air: If it is clean air 70ºC, other depends on the gas (see table in documentation)

UNDER REQUEST:

• Single phase motors (up to 1,1Kw).
• 60Hz fans and special voltages fans.
• 2 speed motors.

Fan

Max flow
5900 m³/h
Weight
35 Kg

Motor

Power
2,2 kW
RPM Motor
2840
I max. 230 V
7,97
I max. 400 V
4,58
Size
90L
Weight
25 Kg
Efficiency
85.9 %
FP
0.83
MBPV 35 T2 2,2kW ATEX Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

MBPV 35 T2 2,2kW ATEX Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)

Dimensions scheme
A B C D E F I L M N O
600 560 240 280 600 50 325 365 540 80 8 490

MBPV 35 T2 2,2kW ATEX Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)

Electrical scheme

MBPV 35 T2 2,2kW ATEX

Model
BA-400 30/31
Code
960002052
Information
ANTI-VIBRATING FLANGE 400º/2H

MANUFACTURING FEATURES

• Flexible polyurethane coupling flange with fiberglass fabric to avoid possible vibrations to the installation.
• 160 mm width and supplied with 2 fixing clamps.
• Certified according to the European standard EN 12101-3 400ºC/2h. Fire classification: M0.

Model
INT 25 ATEX
Code
510200025X
Information
ATEX SWITCH

Switch for ATEX environments. Suitable for zones 1-2 (gas) and 21-22 (dust), index protection IP65. Manufactured in aluminum alloy and RAL 7000 gray finishing coat. External screws in stainless steel. Control on the front. Tensions up to 690V. According to directive 2014/34 / UE (ATEX).

Model
FJ Ø280
Code
FJ-280
Information
PVC FLEXIBLE JOINT

Flexible joint made of PVC

Model
CSC Ø280
Code
CSC280
Information
CIRCULAR GRAVITY DAMPER

PVC/PP Gravity damper

Model
AD Ø280
Code
AD-280
Information
ADJUSTABLE DAMPER

Manual adjustable damper made of PVC/PP

Model
RPI Ø280
Code
RPI280
Information
STAINLESS STEEL PROTECTION GRID

Stainless steel protection grid

Model
SFC 230 I 10A *
Code
SFC230I0010
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
SFC 400 III 5A *
Code
SFC400III5
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

MBPV 35 T2 2,2kW ATEX Zone 2: FAN (Ex h IIB+H2 T4 Gc) + MOTOR (Ex db IIC T4 Gb)