Product out of catalogue
HCFX (F400+ATEX)
Model
HCFX 100 T4/T8 11/3kW (A3:4)
Code
26216634__XW

HCFX 100 T4/T8 11/3kW (A3:4)

SHORT CASE AXIAL ATEX FAN 400ºC/2H

MANUFACTURING FEATURES:

• Axial fan short casing with circular reinforced frame.
• Modular motor-impeller assembly. Cast aluminium impeller with variable pitch angle. Polyester powder finishing coat.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class H insulation certified 400ºC/2h and ATEX Zone 2: fan: Ex h IIB T3 Gc and motor:Ex ec IIC T3 Gc. Manufactured with standard voltages:400V(Y) 50Hz in three phase motors up to 3kW and 400V 50Hz for higher powers and 2 speed motors. IE3 efficiency motor from 0,75kW up to 45kW in single speed
• Protection ring made of aluminium.

APPLICATIONS:

Designed for inline installation, they are suitable for:
• Smoke emergency exhaust with motor inside the hazardous area.
• Maximum working temperature: 60ºC.

UNDER REQUEST:

• Supply impeller (air direction from impeller to motor).
• 100% reversible impeller.

Official homologation by the European laboratory APPLUS according to EN 12101-3:2015
Certification Nr: 0370-CPR-1994

Fan

Max flow
62310 m³/h
Weight
180 Kg

Motor

Power
11/3 kW
RPM Motor
1470/730
I max. 400 V
21,7/7
Size
160M
Weight
119 Kg
Efficiency
86/82,5 %
FP
0,85/0,73
HCFX 100 T4/T8 11/3kW (A3:4)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

HCFX 100 T4/T8 11/3kW (A3:4)

Dimensions scheme
C' E O ØA ØB ØD ØI
718 425 16x22,5º 1115 1070 1013 12

HCFX 100 T4/T8 11/3kW (A3:4)

Electrical scheme

HCFX 100 T4/T8 11/3kW (A3:4)

Model
RP 100
Code
960340103
Information
PROTECTION GUARD FOR LONG CASE FANS

CONSTRUCTION FEATURES

• Protective grille on the motor and propeller side to prevent objects from entering. For HC and HCA models, the RP grille is only applicable on the propeller side. The RP is also suitable for the HMR EVO range, both for intake and discharge (note that the grille is of different sizes depending on whether it is for intake or discharge)
• Constructed with electro-welded rod.
• Compliant with ROHS directive 2002/95/EC.

ON REQUEST

• Grille in 304 or 316 stainless steel with electropolished finish.

Model
PO 100
Code
960001662
Information
CASE FANS MOUNTING SUPPORT

MANUFACTURING FEATURES

• Made of steel and protected against corrosion with polyester resin powder.

Model
AC 1000
Code
960003220
Information
CONECTION FLANGE

MANUFACTURING FEATURES

• For axial (inlet and outlet) and centrifugal (inlet) fans.

UNDER REQUEST

• Versions in stainless 304 and stainless 316.

Model
SIL-C 1000/1000
Code
960100100
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-C 1000/1500
Code
960100150
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-C 1000/2000
Code
960100200
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 1000/1000
Code
961100100
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 1000/1500
Code
961100150
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
SIL-CN 1000/2000
Code
961100200
Information
CIRCULAR SILENCER

MANUFACTURING FEATURES

• Valid for mounting in inlet and outlet according to the diameter of the corresponding pipe or adapted to the diameter of an optional flange. Consult to Casals Ventilación.
• Steel housing with thickness of 0.8mm for diameters up to 1250mm; and 1mm for higher diameters.
• Silencer flange with threaded inserts.
• Acoustic rock wool insulation of 70Kg/m3 with microperforated metal mesh that protects the fiberglass from erosion. Fire resistant insulation M0.
• Attenuation test carried out according to the ISO 7235 standard.
• Drills in accordance with Eurovent regulations.
• SIL-CN are equipped with an inner core that increases silencer attenuation.
• Maximum working temperature: 150ºC.
• Suitable for pressures up to 1000Pa

APPLICATIONS

• For attenuating the sound level of the fan.
• For coupling fans and circular pipes.

Other sizes, consult us.

Model
INT 400 40A 6P
Code
508904002
Information
SAFETY SWITCH FOR 400ºC/2h

Safety switch for local disconnection of 400ºC/2h ventilation equipments according to UNE-EN 12101-3.
Suited for direct control of motor in AC 3 operation category
Equips two auxiliary contact.

Model
RP1 1003
Code
960003612
Information
INLET PROTECTION GUARD FOR AXIAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of welded metal wire.
• According to ROHS 2002/95/EC Directive.

UNDER REQUEST

• Stainless guard 304 or 316 with electro-polished finishing coat.

Model
BAD 19 (Ø1000)
Code
960003469
Information
CIRCULAR-CIRCULAR ANTI-VIBRATION FLANGE

MANUFACTURING FEATURES

• Circular-circular coupling flange through anti-vibration canvas.
• Fire resistance M0: from -50ºC to +200ºC in continuous and 400ºC/2h

Model
KIT TE 100
Code
KTE100
Information
ROOF KIT FOR CASE FANS

Set that allows to install short or long case fans on the roof protecting them from inclement weather. Kit not suitable for fire (fiber cowl -20+110ºC).

MANUFACTURING FEATURES

Set consisting of:

• Cowl made of reinforced glass fiber protection cowl.
• Support framework for roof adaptation in laminated steel sheet protected against corrosion by powder coating polyester resin.
• Anti-bird protection grid protected against corrosion.

APPLICATIONS

Designed for roof installation, they are indicated for:
• Renovation of air in all types of buildings and industries.
• Smoke extraction.
• Contribution of clean air.
• Maximum temperature subject to installed fan.

The kit musn't be installed if the air speed is higher than 13m/s

UNDER REQUEST

• Framework support in AISI 304,316.
• Cold galvanized steel.
• Hot galvanized steel.

 

Model
KIT TM 100
Code
KTM100
Information
METALLIC ROOF KIT FOR CASE FANS

Set that allows to install short or long case fans on the roof protecting them from inclement weather. Kit suitable for fire (metal cap).

MANUFACTURING FEATURES

Set consisting of:
•Cowl made of galvanized sheet.
• Support framework for roof adaptation in laminated steel sheet protected against corrosion by powder coating polyester resin.
• Anti-bird protection grid protected against corrosion.

APPLICATIONS

Designed for roof installation, they are indicated for:
• Renovation of air in all types of buildings and industries.
• Smoke extraction.
• Contribution of clean air.
• Maximum temperature subject to installed fan.

UNDER REQUEST

• Framework support in AISI 304,316.
• Cold galvanized steel.
• Hot galvanized steel.

HCFX 100 T4/T8 11/3kW (A3:4)

Spare parts scheme
Code Family Name Qty Angle
1 R-H10034732FSTD IMPELLER 1000:AF3:4 G32 D42 x1 32
1 R-H10034734FSTD IMPELLER 1000:AF3:4 G34 D42 x1 34
1 R-H10034736FSTD IMPELLER 1000:AF3:4 G36 D42 x1 36
1 R-H10034738FSTD IMPELLER 1000:AF3:4 G38 D42 x1 38