ATEX INLINE SOUNDPROOF CABINET AXIAL
MANUFACTURING FEATURES
• BOX: Soundproof galvanised steel box with thermo-acoustic insulation, Bs1d0 fire class. Easy motor access and fan maintenance through removable panels.
• Internal fan coil round frame reinforced with intermediate rib and sparking aluminum ring. Modular design of the motor impeller assembly allows complete versatility in case of any change. Aluminum impeller variable pitch angle. Corrosion-resistant powder coat polyester resin.
• Motor ATEX asíncrono normalizado. Certificado según zona indicada, IP55 and class F insulation. Manufactured with standard voltages: 230/400V 50Hz for three phase motors up to 4kW and 400/690V 50Hz for higher powers.
APPLICATIONS
Designed for wall or duct installation, indoor or outdoor assembly, they are suitable for:
• Air renewal in buildings and industries.
• Smoke extraction (max 40ºC).
• Ventilation in indoor environments classified as ATEX
• Working temperature: ambient from -20ºC to 40ºC
UNDER REQUEST
• B form or 100% reversible impeller.
• 60 Hz fans and special voltages.
__________________________________
ORGANISM: L.O.M.
CERTIFICAT Nº: LOM 17.755X-C
In compliance with the Directive 2014/34/UE
A | B | C | D | E | F | G | H | J | K | L | M | N | O |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
781,5 | 781,5 | 542 | 630 | 76 | 630 | 76 | 30 | 665 | 610 | 11 | 715 | 35 | 60 |
MANUFACTURING FEATURES
• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.
*Máx. thermal current air (A)
MANUFACTURING FEATURES
• Flexible joint to clinch the fan to the duct.
• Avoids transmission of vibrations for circular and rectangular connection.
• Dimensions: two metallic flanges of 45mm each one and a flexible flange of 60mm.
• The reel is 30,5m lenght.
• Maximum pressure: 20 mmca.
• Fire resistance M0 from -50ºC to +200ºC in continuous and 400ºC/2h.
MANUFACTURING FEATURES
• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.
*Dial panel incorporated. Optional EMC filter.
Certifications: CE/UL/CSA/EN/GOST/CCC.
Protection index IP20.
The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.
SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III
EMC filter incorporated for models from 47A (included)
*Lineal load rated current
**Quadratic load rated current
MANUFACTURING FEATURES
• Outdoor flange with bird guard for BOX HB.
• Made of galvanized Steel.
Depression damper for ascending air flow in the intake. The slats block the passage of air when the fan is stopped while when the fan is running the slats move by depression allowing the passage of air. Robust U-shaped frame. The special holes in the corners allow a connection with common union systems on the market such as a duct working in plenum mode. It maintains the overpressure or depression inside a room with respect to the outside or another adjoining room.
MANUFACTURING FEATURES:
- Galvanized steel frame, U-shaped to install in a duct.
- Aluminum slats.
- Ø12 shafts in galvanized steel.
- Ø12 bronze bushings.
- Suitable for 400°/2h (not certified) and temperatures below zero.
- It can be installed directly to the fan, although the use of the frame (B CMP) is recommended.
- Suitable for speed 18 m/s and with some turbulence.
Nº | Code | Family | Name | Qty |
---|---|---|---|---|
1 | R-H56056325XSTD | IMPELLER | 560:AX5:6 G25 D19 | x1 |
2 | 721601138 | MOTOR | 0,55KW 1500 B3 230/400V II2G IIC T4 Ex-d Gb IP66 | x1 |