Product out of catalogue
HB
Model
HB 112 T4/T8 5,5/1,1kW (A6:3)
Code
26023663__PV

HB 112 T4/T8 5,5/1,1kW (A6:3)


WALL FAN , VARIABLE PITCH BLADES

MANUFACTURING FEATURES:
• Plate axial fan with circular reinforced frame.
• Motor-impeller modular assembly for complete versatility.
• Corrosion-resistant powder coat polyester resin.
• Standard asynchronous squirrel-cage motor with IP-55 protection and Class F insulation. Manufactured with standard voltages: 230V 50Hz for single phase motors, 230/400V 50Hz for three phase motors up to 4kW and 400/690V 50Hz for higher powers 1 speed and 400V for 2 speed motors.
• HB :Polypropylene impeller (A2 profile) or polyamide impeller reinforced with fibreglass (other profiles) with variable pitch angle.
• HBA : Cast aluminum impeller with variable pitch angle.

APPLICATIONS:
Designed for wall or duct installation, they are suitable for:
• Air renewal in buildings and industries.
• Maximum working temperature: 1ph 50ºC, 3ph 60ºC.

UNDER REQUEST:
• Supply impeller (air direction from impeller to motor)
• 100% reversible impeller.
• 60Hz fans and special voltages.
• Hot-dipped galvanized or stainless steel housing.

Fan

Max flow
52710 m³/h
Weight
115 Kg

Motor

Power
5,5/1,1 kW
RPM Motor
1450/720
I max. 400 V
11/27,2
Size
132S
Efficiency
84/74 %
FP
0.85/0.54
HB 112 T4/T8 5,5/1,1kW (A6:3)
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

HB 112 T4/T8 5,5/1,1kW (A6:3)

Dimensions scheme
C E O ØA ØB ØDint ØJ
760 340 16x22,5º 1234 1190 1132 12

HB 112 T4/T8 5,5/1,1kW (A6:3)

Electrical scheme

HB 112 T4/T8 5,5/1,1kW (A6:3)

Model
RP1 1122
Code
960003621
Information
INLET PROTECTION GUARD FOR AXIAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of welded metal wire.
• According to ROHS 2002/95/EC Directive.

UNDER REQUEST

• Stainless guard 304 or 316 with electro-polished finishing coat.

Model
RP0 1120
Code
960001213
Information
Outlet protection guard for axial fans

MANUFACTURING FRATURES

• Protection grid on the outlet side to avoid the entry of objects and contact with the impeller.
• Made of welded metal wire.
• According to ROHS 2002/95/EC Directive.

UNDER REQUEST

• Stainless guard 304 or 316 with electro-polished finishing coat.

Model
INT 32 6P A
Code
INT326PA
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)