Product out of catalogue
ARUMAK LP
Model
ARUMAK LP 1000 ePM1≥70%/ePM1≥70% (ex. F7/F7) CTRL-F
Code
AL10SH1F00F7

ARUMAK LP 1000 ePM1≥70%/ePM1≥70% (ex. F7/F7) CTRL-F

LOW PROFILE COUNTER FLOW ENERGY EXCHANGER FOR FALSE CEILING

MANUFACTURING FEATURES
Medium-high efficiency energy recovery unit (Eff.78%). Low profile with electronic regulation and AC mo- tor for optimized management. Counter flow energy exchanger, Eurovent certified. Set in insulated steel boxes with sandwich polyurethane foam panels. With partial bypass and regulation control CTRL-F and CTRL-DPH (see options in control panel in documentation). With MERV 13 (F7)/MERV 13 (F7) or MERV 13 (F7)+MERV 15 (F9)/MERV 13 (F7) filters.

Horizontal and false ceiling installation version

CHASSIS:
•    Modular structure made of extruded aluminium profiles and double skin Aluzinc.
•    Made up of sandwich panels with injected polyure- thane foam insulation, thickness 25 mm and density 42 kg/m3.

HEAT EXCHANGER:
•    Aluminium Counter flow heat exchanger with 78% efficiency.
•    Eurovent certified.

FANS:
•    Centrifugal fans with direct motor coupled with double suction according to ErP 2018.

FILTERS:
•    MERV 13 (F7)/MERV 13 (F7) or MERV 13 (F7)+MERV 15 (F9)/MERV 13 (F7) filters.
 
CONTROL:
•    CTRL-F: 4 speeds, ON / OFF bypass, 3 tempera- tures and indication of filter failure. o portable
display. Optional: portable display with connection cables.

•    CTRL-DPH: manual speed, manages bypass auto- matically. Regulation of fresh air, fault detection and time programming.

APPLICATIONS
•    Shopping centers, small shops, banks, hospitality, schools, office buildings, public buildings.

UNDER REQUEST


•    Without control
•    Manual bypass.
•    MERV 15 (F9)/MERV 13 (F7) filters.
•    CTRL-MAX2 with Modbus RTU protocol

CONFIGURATIONS
•    Other special configurations under request

See maintenance video

 

Fan

Max flow
1020 m³/h
Weight
91 Kg

Motor

Power
2x0.29 kW
RPM Motor
1920
I max. 230 V
2x0,29
ARUMAK LP 1000 ePM1≥70%/ePM1≥70% (ex. F7/F7) CTRL-F
Loading...
Design point
Loading...
Service point
Loading...
Alternative point

ARUMAK LP 1000 ePM1≥70%/ePM1≥70% (ex. F7/F7) CTRL-F

Dimensions scheme
A B C E Ø
430 1200 1150 215 250

ARUMAK LP 1000 ePM1≥70%/ePM1≥70% (ex. F7/F7) CTRL-F

Electrical scheme

ARUMAK LP 1000

Model
VISC Ø250
Code
FX0045450
Information
CIRCULAR OUTDOOR FLANGE WITH BIRD GUARD

MANUFACTURING FEATURES

• Circular outdoor flange with bird guard made of galvanized steel.

Model
DCO2
Code
DCO2ST
Information
TEMPERATURE, RELATIVE HUMIDITY AND CO2 DUCT PROBE FOR HEAT EXCHANGERS

Duct sensor for measuring temperature, relative humidity and CO2 in the rooms.
Optional: The CO2 modules can be removed from the sensor to be calibrated.