• The control can manage up to a total of 6 decentralized recovery units.
• In VENTILATION or RECOVERY modes, the recovery units will start to ensure the balance of the general flow in ventilation mode with heat recovery.
Heat recovery mode
• Winter: Extracted air from the room (hot) is exploited to pre-heating the air supplied to the room (cold).
• Summer: Extracted air from the room (cold) is exploited to pre-cooling the air supplied to the room (hot).
• The connected devices cyclically reverse the direction of fan rotation (extracting and introducing air into the environment) with a set cycle time.
• Speed adjustment (of devices) is automatic and ensures the correct ba-lance of the Input/Output flow rates.
Ventilation Mode
• The devices change internal environment air (without recovering heat).
- Even number devices extract air from the environment.
- Odd number devices introduce air into the environment.
• Speed adjustment (of devices) is automatic and ensures the correct ba-lance of the Input/Output flow rates.
Air Extraction Mode
• All connected devices extract air from the internal environment.
• The air flow rates are all in Output toward the external environment.
Input 230Vac 50/60Hz (N=Blue, L= Brown)
Output: 12 Vdc-2A 24W (+=Red, -= Black)
Working temperature: -10ºC/50ºC
Input 230Vac 50/60Hz (N=Blue, L= Brown)
Output: 12 Vdc-3A 36W (+=red, -= Black)
Working temperature: -10ºC/50ºC
Input 100-240Vrms 50/60Hz
Output: 12 Vdc-3A 36W
Working temperature: -10ºC/50ºC
Metal panel “windbreak” for exterior in stainless steel sheet.
External rubber grille that can be installed from the inside wthi out the need for scaffolding.
90° Circular / Square Adapter for entry and exit through a window jamb.
Rectangular stainless steel grill for ACC window adapter kit
Rectangular grid in powder-coated stainless steel, white RAL 9003, for kit.
Sensor to control the air temperature in the room: allows automatic start or speed change of the combined product when the temperature exceeds the preset value, selectable by external trimmer and adjustable in the range 10°C - 40°C. A timer allows the appliance to operate for a predetermined time, which can be set during installation from 3 to 20 minutes, after the temperature has dropped below the predetermined threshold.
Single-phase 220-240V / 50- 60 Hz power supply. Wall installation.
The color white.
Maximum allowable load: 3A.
Enclosure for wall installation with IP20 protection.
Sensor for controlling the rate of relative humidity (RH) in the air: allows automatic start or speed switching of the combined product when the percentage of RH exceeds 65%. If the humidity does not exceed the threshold, the associated appliance turns on automatically a few seconds after the light is turned on and continues to operate, after it is turned off, for a preset time, which can be set during installation from 3 to 20 minutes .
Single-phase power supply 220-240 V / 50-60 Hz. Wall installation. The color white.
Maximum admissible load: 3 A.
Enclosure for wall installation with IP20 protection.
Sensor para el control de la tasa de humedad relativa