KUVIO-Q 100 EEC

Model
REGC
Code
FX263300
Information
SPEED CONTROLLER FOR EEC MOTOR

MANUFACTURING FEATURES

• Speed remote controller for EEC motors.
• Adjusts the flow rate in a range from 0 to 100% at a maximum distance of 10m.
• It can be recessed or mounted on a wall. Can be installed outdoors.
• Working temperature from 0 to 40ºC.

Model
C-ISOL D.100
Code
CISOL100
Information
DUCT SUSPENSION CLAMP

Duct Suspension M8 Isophonic clamp for rigid circular ducts in galvanised steel with elastomer seal liner. Rapid hanging system for diameters 400 mm and smaller. Prevents transmission of vibrations. Easy set up.

UNDER REQUEST:

In stainless steel.

Model
C-FLEX D.90-115
Code
CFLEX90115
Information
STRAP CLAMP

Strap clamp for flexible circular duct. Made of stainless steel. AISI 430. Prevents the transmission of vibrations and is easy to install for diameters up to 320mm.

Model
SILC-MINI 100
Code
SILCM100
Information
CIRCULAR SOUND ATTENUATOR IN GALVANISED STEEL

The sound attenuators are used to absorb the noise in air conditioning or ventilation ducts.

Casing in galvanised steel, thickness 0,8 mm;
Mounting flange with quick attack;
Acoustic material in mineral wool  50 Kg /m³ with protection against erosion by glass fibre fire resistance M0 and extended metal sheet

 UNDER REQUEST:

Stainless steel execution

Model
BDC Ø 100
Code
BDC100
Information
BACKDRAUGHT SHUTTER

Galvanized sheet-metal backdraught shutter with aluminium fins and return springs to install in the discharge of the fans. They prevent odors, air currents, water penetration due to rain when the fans are off and prevent heating leaks when the extractor does not work.

Model
STEMP
Code
STEMP3A
Information
SENSOR TO CONTROL THE AIR TEMPERATURE

Sensor to control the air temperature in the room: allows automatic start or speed change of the combined product when the temperature exceeds the preset value, selectable by external trimmer and adjustable in the range 10°C - 40°C. A timer allows the appliance to operate for a predetermined time, which can be set during installation from 3 to 20 minutes, after the temperature has dropped below the predetermined threshold.
Single-phase 220-240V / 50- 60 Hz power supply. Wall installation.
The color white.
Maximum allowable load: 3A.
Enclosure for wall installation with IP20 protection.

Model
SHR
Code
SHR3A
Information
SENSOR TO CONTROL THE RATE OF RELATIVE HUMIDITY

Sensor for controlling the rate of relative humidity (RH) in the air: allows automatic start or speed switching of the combined product when the percentage of RH exceeds 65%. If the humidity does not exceed the threshold, the associated appliance turns on automatically a few seconds after the light is turned on and continues to operate, after it is turned off, for a preset time, which can be set during installation from 3 to 20 minutes .
Single-phase power supply 220-240 V / 50-60 Hz. Wall installation. The color white.
Maximum admissible load: 3 A.
Enclosure for wall installation with IP20 protection.
Sensor para el control de la tasa de humedad relativa

Model
PMR 25A
Code
PMREEC
Information
SPEED CONTROLLER WITH SAFETY SWITCH FOR EEC MOTOR

CONSTRUCTIVE FEATURES
• Remote control of speed regulator for EEC motors.
• Allows you to adjust the flow in a range from 0 to 100%, at a maximum distance of 10m.
• Stop-start safety switches according to IEC 60947-1 and IEC 60947-3.
• IP66 and always equipped with an auxiliary contact.
• Useful for cutting off the power before handling the fan.
• Working temperature from -20ºC to 40ºC.

Model
VISC Ø100
Code
VISC100
Information
CIRCULAR OUTDOOR FLANGE WITH BIRD GUARD

MANUFACTURING FEATURES

• Circular outdoor flange with bird guard made of galvanized steel.