HB 112 T6 (A6:3)

Model
RP0 1120
Code
960001213
Information
Outlet protection guard for axial fans

MANUFACTURING FRATURES

• Protection grid on the outlet side to avoid the entry of objects and contact with the impeller.
• Made of welded metal wire.
• According to ROHS 2002/95/EC Directive.

UNDER REQUEST

• Stainless guard 304 or 316 with electro-polished finishing coat.

Model
SFC (GENERIC)
Code
Information
FREQUENCY SPEED CONTROLLER

MANUFACTURING FEATURES

• Specially designed for speed frequency control in ventilation applications.
• Ultra compact, simple operation and wide range of functions.

*Dial panel incorporated. Optional EMC filter.

Certifications: CE/UL/CSA/EN/GOST/CCC.

Protection index IP20.

The selection of SFC frequency drive speed controller must be made based on the maximum intensity absorbed by the fan to be regulated. The powers (kW) and the intensity for constant load refer to the normal duty (150% overload for 60 seconds). The intensity for quadratic load admits an overload of 110% during 60s.

SFC 230: Entrance 230V I, exit 230V III
SFC 400: Entrance 400V III, exit 400V III

EMC filter incorporated for models from 47A (included)

*Lineal load rated current

**Quadratic load rated current

Model
INT (GENERIC)
Code
Information
SAFETY SWITCH

MANUFACTURING FEATURES

• Safety start-stop switches according to IEC 60947-1 and IEC 60947-3.
• IP65 and always equipped an auxiliary contact.
• Useful for switching off the current before handling the fan.

*Máx. thermal current air (A)

Model
RP1 (GENERIC)
Code
Information
INLET PROTECTION GUARD FOR AXIAL FANS

MANUFACTURING FRATURES

• Inlet protection guard to avoid the entry of objects and contact with the impeller.
• Made of welded metal wire.
• According to ROHS 2002/95/EC Directive.

UNDER REQUEST

• Stainless guard 304 or 316 with electro-polished finishing coat.

Model
CMP-HLT 1250x1250
Code
CMPHLT125125
Information
OVERPRESSURE DAMPER (VERTICAL POSITIONING)

Non-return overpressure damper for façades made of aluminum slats, which opens and closes automatically. It works with the airflow by opening during operation and closing when the fan is closed. L-shaped frame to be directly embedded. It maintains the overpressure or depression inside a room with respect to the outside or another adjoining room. They incorporate holes in the frame for fixing to the wall or duct by means of screws or rivets.

CONSTRUCTIVE FEATURES:

- Galvanized steel frame for embedding, L-shaped.

- Aluminum slats.

- Ø12 shafts in galvanized steel.

- Ø12 bronze bushings.

- Suitable for 400°/2h (not certified) and temperatures below zero.

- Suitable for speed 18 m/s and with some turbulence.