Casals
ESPAÑOL   |   ENGLISH
  • Products
    BUILDING TECHNICAL VENTILATION INDUSTRIAL VENTILATION ELECTRICAL ACCESSORIES MECHANICAL ACCESSORIES
    Search by series Selection software Request technical advice now Product certificates Applications
    ERELIS residential extractor fan ORMEN EC residential energy recovery unit REINTDECK EC tertiary purifier for false ceiling
  • Novelties
  • Applications
    • Ventilation in car parks in case of fire
    • Car parks extraction and CO detection
    • Bathroom extractor fans
    • Machine cooling
    • Ventilation of industrial buildings
    • Corrosive environments
    • Paint booths
    • Forges
    • Pneumatic transport
    • Special applications
    • Dust and gas ATEX
    • Industrial processes
    • Ventilation for medicinal cannabis cultivation
    • Risks of carbon dioxide in cellars and ventilation
    • Fans for marine and offshore applications
    • Industrial kitchens
    • HOTELS
    • Shopping malls
    • Cinemas
    • Classroom- Universities or schools
    • ENTRANCES
    • SHOPS
    • OFFICES
    • WET AREAS
    • Farms
    • GREENHOUSES AND CROPS
    • Forage dehydration
    • Domestic garages
    • Barbecues and fireplaces
    • Housing ventilation
    • Rooms purification against virus and improve IAQ
  • Ventilation tools
    • Concepts
    • Types of fans
    • Calculation help
    • Converter
  • Selection software
  • Documentation
    • Certificates
    • Manuals
    • Standards
    • Document library
    • Price lists
  • Company
    • History
    • Corporative video
    • Main Casals projects
    • Ethical channel
  • Casals Service
  • Contact
    • Contact
    • National sales network
    • International sales network
    • Visit our factory
    • Cooperation
  • Products
  • Novelties
  • Applications
  • Ventilation tools
  • Selection software
  • Documentation
  • Company
  • Casals Service
  • Contact
  • News
  • Español
Casals > Products > BUILDING TECHNICAL VENTILATION > TERTIARY HEAT RECOVERY UNITS
Search by series Casals technical catalogue Advice

TERTIARY HEAT RECOVERY UNITS: ABRENSA EEC

This product is currently out of catalog. Contact us for a better solution. Sorry for the inconvenience.
Print Send Technical data sheet

HEAT RECOVERY UNIT, HALF-HIGH EFFICIENCY WITH COUNTER FLOW CELL EXCHANGER AND EEC TECHNOLOGY

CONSTRUCTIVE FEATURES:

Medium efficiency heat recovery unit (74%) with EC motor for optimized management, and Eurovent certified counter flow exchanger.
Mounted in insulated steel boxes with double wall panels of 25mm thickness.
Equipped with filters ISO ePM1 70% (F7)/ISO ePM1 70% (F7) or ISO ePM1 70% (F7) +ISO ePM1 >80% (F9)/ISO ePM1 70% (F7).
Versions for vertical and horizontal installation with complete bypass.

CHASSIS:
• Modular structure in 30mm extruded aluminum profile with reinforced nylon corners.
• 25 mm thick double walled panels made of galvanized steel sheet with epoxy polyester, according to EN10327 and EN10192 with polystyrene insulation with a density of 30 Kg / m3.

HEAT EXCHANGER:
• Aluminum counterflow heat exchanger with 74% efficiency.
• Recuperator brand and certified by Eurovent.

FANS:
• Centrifuges with double suction direct motor and according to ISO 1940 and AMCA 204-G.25 standards.

FILTERS:
• Filters ISO ePM1 70% (F7)/ISO ePM1 70% (F7)+ ISO ePM1 >80% (F9)/ISO ePM1 70% (F7)

CONTROL:
• CTRL-MAX: has a screen interface that allows an intuitive view of the operating state of the equipment; allows the timely regulation of fan speed and programming a weekly schedule for automatic fan management. It can control any accessory for the post-air treatment, manages the bypass automatically and avoids the heat exchanger brine by managing the fan speed and signals to the user the need to replace the filter (the state of obstruction of the filters is monitored by a pair of differential pressure switches as standard) or the start of an anomaly that indicates its origin. On demand the control that allows to choose the modes of constant flow (CAV), variable flow (VAV) and constant pressure (COP). To make these options functional, the unit must be ordered with the COP KIT, CAV KIT or KIT COP (under request). It also allows automatic temperature management.

APPLICATIONS:
Shopping centers, small shops, banks, hotels, schools, office buildings, public buildings.

UNDER REQUEST
Modbus RS485 and additional remote display.
Plug & play version (integrated pre-wired control and control panel).
Kit COP + CAV, VAV.
ISO ePM1 >80% (F9) in return.
Electric preheating battery.
It can be equipped with post-treatment air systems with a cold water battery installed outside the unit.

 

Contact now
Treatment responsible: CASALS VENTILACIÓN AIR INDUSTRIAL S.L.
Purpose of processing: Maintain a relationship with the User and send the newsletter.
Legitimation: Consent of the interested party.
Data retention: They will be kept for as long as there is a mutual interest or for the time necessary for the fulfillment of legal obligations.
Data recipient or session: CASALS VENTILACIÓN AIR INDUSTRIAL S.L. and service providers or collaborators.
Data subject rights: Right to withdraw consent at any time. Right of access, rectification, portability and deletion of your data and the limitation or opposition to its treatment. Contact information to exercise your rights: data@casals.com
Additional information: You can view the additional information in our Privacy Policy.
Captcha no verificado
Building security systems in case of fire
Casals
+34 972 720 150
News
CASALS VENTILACIÓN AIR INDUSTRIAL, SLU
Ctra. Camprodon, s/n
17860 Sant Joan de les Abadesses (Girona)
SPAIN
© Casals, 2025  |  Legal notice  |  Privacy Policy  |  Cookies policy
VORTICE Group worldwide
International    Italy    United Kingdom    China    Latam    Casals    Vortice Industrial

Use of Cookies

We use our own and third-party cookies to analyze your browsing habits and to be able to offer you our web content according to your interests. Access to our Cookies Policy for more information. If you click “Accept” we take that you have been informed and accept their use. You can also configure them or reject their use clicking HERE

Cookies policy

Cookies configuration

Here you can configure your preferences and choose which cookies you allow to be installed on your device pressing "Accept" or deny their installation pressing "Reject" in each of them:

TECHNICAL COOKIES These cookies are necessary for the operation of the website and cannot be deactivated on our systems.
 
ANALYTICAL COOKIES
 
STATISTICAL COOKIES

For more information see our Cookies Policy